• Up to 5A 120VAC or 28VDC rating, also available in gold
• Panel or PC board mount design
• Up to 4 poles momentary and maintained functions |
 |
• Up to 5A 120VAC or 28VDC rating, also available in gold
• Panel or PC board mount design
• Up to 2 poles momentary and maintained functions
• IP67 sealed |
 |
• Up to 3A 120VAC or 28VDC rating, also available in gold
• PC board mount design
• 1 or 2 pole momentary and maintained functions |
 | • Up to 3A 120VAC or 28VDC rating, also available in gold
• PC board mount design
• 1 or 2 pole momentary and maintained functions
• IP67 sealed |
 | • 3A 120VAC rating, also available in gold
• Surface mount design
• 1 pole momentary and maintained functions
• IP67 sealed |
 |
• 15A 125VAC rating
• 13mm x 19.2mm panel cutout
• Full LED illumination options |
 | • 9A 125VAC rating
• 13mm x 19.2mm panel cutout
• Full illumination options
• 1 or 2 pole maintained functions |
 |
• 20A 125VAC rating
• 11mm x 30mm panel cutout
• Full illumination options |
 | • 20A 125VAC rating
• 22mm x 30mm panel cutout
• Full illumination options |
 | • 10A 125VAC rating
• 6.65mm x 19.2mm panel cutout
• 1 pole maintained and momentary functions |
 | • Up to 16A 125VAC rating
• 13mm x 19.2mm panel cutout
• Full illumination options |
 | • Up to 16A 125VAC 1/3HP rating
• 22mm x 19.2mm panel cutout
• 1 or 2 pole maintained and momentary functions |
 | • Up to 16A 125VAC 1/3HP rating
• 22mm x 19.2mm panel cutout
• 1 or 2 pole maintained and momentary functions |
 | • 16A 125VAC rating
• 13mm x 19mm panel cutout
• 1 or 2 pole maintained functions |
 | • 20A 125VAC 3/4HP rating
• 11mm x 30mm panel cutout
• Full or spot illumination options |
 | • 20A 125VAC 3/4HP rating
• 22mm x 30mm panel cutout
• Full or spot illumination options |
 | • 16A 125VAC rating
• 22mm x 30mm panel cutout
• Full or spot illumination options |
 | • 16(16)A 125VAC 1/3HP rating
• 22mm x 30mm panel cutout
• Full illumination options
• IP66 rated |
 | • Up to 16A 125VAC 1/3HP rating
• 6.8mm x 19.4mm panel cutout
• 1 pole Off-On function |
 | • Up to 16A 125VAC 1/3HP rating
• 13.5mm x 23.3mm oval panel cutout
• Full illumination options |
 | • Up to 16A 125VAC 1/3HP rating
• 20mm diameter panel cutout
• Full and spot illumination options |
 | • 16A 125VAC rating
• 20.2mm diameter panel cutout
• Full illumination options
• 1 pole momentary and maintained functions |
 | • 10A 125VAC rating
• 18.2mm diameter panel cutout
• 1 or 2 pole maintained functions |
 |
• 6A 125VAC rating
• 15mm diameter panel cutout
• Paddle actuator design
• 1 pole maintained functions |
 | • 20A 125VAC rating
• 20mm diameter panel cutout
• 1 pole maintained and momentary functions |
 | • Up to 16A 125VAC 1/3HP rating
• 20mm diameter panel cutout
• Full illumination options |
 | • Up to 15A 125VAC 1/3HP rating
• 22mm diameter panel cutout
• Full illumination options |
 | • Up to 16A 125VAC 1/3HP rating
• 20mm diameter panel cutout
• 1 pole maintained and momentary functions |
 | • Up to 16A 125VAC 1/3HP rating
• 22mm diameter panel cutout
• 1 pole maintained and momentary functions |
 | • 20A 125VAC 1/4HP rating
• Full illumination options
• 4 different panel cutouts ranging between 12.1 and 13.9mm x 27.2 and 28.6mm |
 | • 20A 125VAC 2HP rating
• 37.5mm x 21mm panel cutout
• 1 or 2 pole maintained and momentary functions
• IP54 rated |
 | • Up to 20A 125VAC 2HP
• 22mm x 30mm panel cutout
• 2 pole maintained and momentary functions
• IP55 rated
|